AirGuard 15kV

AirGuard 15kV

Armored Cable AirGuard 15kV

AirGuard 15kV

3AG-0203, 3AG-1013, 3AG-2023, 3AG-4043, 3AG-3503, 3AG-5003, 3AG-7503

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable AirGuard 15kV

Cables y sistemas Prysmian
aislamiento de EPR
Airbag capa de alta resistencia
El forro de PVC
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B compacto hebra concéntrica suave extraer el cobre recocido de acuerdo con ASTM
2. conductor de la pantalla: blindaje semiconductor extruido termoestable que es libre de extracción del conductor y se une al aislamiento
3. Aislamiento: aislamiento de EPR a base de naturales de alta resistencia dieléctrica EPROTENAX, combinado con otros materiales y agentes que mejoran la eléctrica y mecánica
características que aseguran la vida cable extendido
4. METÁLICO SHIELD: aplicada helicoidalmente cinta de cobre no magnética (s) sobre blindaje de aislamiento con una superposición mínima de 15%. Una cinta de aluminio / poliéster se aplica longitudinalmente
bajo el escudo de cinta de cobre para la identificación de fase – un conductor con rojo, un conductor con el azul, y un conductor con negro
5. Conductores a tierra: Conductor desnudo de cobre trenzado, uno en cada intersticio, por UL, ICEA y ASTM
6. MONTAJE: Fase identificado conductores blindados cableadas con materiales de carga y conductores de tierra (como se especifica), formando un núcleo de cable firme y cilíndrica. Se aplica una cinta con aglutinante
para mantener la simetría del núcleo y estabilidad mecánica
7. Protección mecánica: de alta resistencia y la capa Airbag alta resistente al aplastamiento cubierta extruida del conjunto de núcleo
PROTECCIÓN 8. química: Una capa de Drylam que consiste en cinta de aluminio y una capa de polímero extrudido resistente a productos químicos se aplica
9. CHAQUETA: La luz solar resistente al cloruro de polivinilo (PVC)
10.STANDARDS: Listado Tipo MV-105 por UL 1072 y MSHA Tipo MP, cumple con los requisitos de 93-639 S-ICEA (WC74). Identificado para uso de la TC. Cable pasa IEEE 1202 / T4 libre (70.000 Btu / hr)
y ICEA T-29-520 (210.000 Btu / h) ensayos a la llama
11.AMPACITY: Basado en una temperatura ambiente de 40 ° C, cable aislado en el aire por la tabla NEC 2008 310.71
12.TEMPERATURE: 105 ° C
13.VOLTAGE: 15 kV
APLICACIONES
Para las instalaciones en ambos lugares expuestos y ocultos, de acuerdo con NEC. Para la instalación en lugares húmedos y secos, de acuerdo con NEC. Puede ser enterrado directamente o
incrustado en el hormigón. Para la instalación de bandejas portacables, bandejas, bastidores metálicos, instalación de la antena y el cable rígido continua apoya de acuerdo con NEC. Adecuado para
aplicaciones verticales verticales. Adecuado para Clase I División 2 lugares. Prysmian, 

Armored Cable AirGuard 15kV

PRYSMIAN CABLES & SYSTEMS
EPR insulation
High strength Airbag layer
PVC jacket
SPECIFICATIONS OF
1. CONDUCTOR: Class B Compact concentric strand soft drawn annealed copper per ASTM
2. CONDUCTOR SHIELD: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation
3. INSULATION: Natural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical
characteristics assuring extended cable life
4. METALLIC SHIELD: Helically applied non-magnetic copper tape(s) over insulation shield with a minimum overlap of 15%. A aluminum/polyester ribbon is longitudinally applied
under the copper tape shield for phase identification – one conductor with red, one conductor with blue, and one conductor with black
5. GROUNDING CONDUCTORS: Bare stranded copper conductor, one in each interstice, per UL, ICEA and ASTM
6. ASSEMBLY: Phase identified shielded conductors cabled with fillers and grounding conductor (as specified), forming a firm and cylindrical cable core. A binder tape is applied
to maintain core symmetry and mechanical stability
7. MECHANICAL PROTECTION: High-strength and high-crush-resistant Airbag layer extruded cover the core assembly
8. CHEMICAL PROTECTION: A layer of Drylam which consists of aluminum tape and a chemical-resistant extruded polymer layer is applied
9. JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) jacket
10.STANDARDS: Listed Type MV-105 per UL 1072 and MSHA Type MP, meets ICEA S-93-639 (WC74) requirements. Identified for CT use. Cable passes IEEE 1202/FT4 (70,000 Btu/hr)
and ICEA T-29-520 (210,000 Btu/hr) flame tests
11.AMPACITY: Based on an ambient temperature of 40°C, cable isolated in air per 2008 NEC table 310.71
12.TEMPERATURE: 105°C
13.VOLTAGE: 15 kV
APPLICATIONS
For installations in both exposed and concealed locations in accordance with NEC. For installation in wet and dry locations in accordance with NEC. May be directly buried or
embedded in concrete. For installation on cable trays, troughs, metal racks, aerial installation and continuous rigid cable supports in accordance with NEC. Suitable for
vertical riser applications. Suitable for Class I Division 2 locations.

3AG-0203, 3AG-1013, 3AG-2023, 3AG-4043, 3AG-3503, 3AG-5003, 3AG-7503

Armored Cable AirGuard 15kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

AirGuard 5kV

AirGuard 5kV

Armored Cable AirGuard 5kV

AirGuard 5kV

3AE-0203, 3AE-1013, 3AE-2023, 3AE-4043, 3AE-3503, 3AE-5003

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable AirGuard 5kV

Cables y sistemas Prysmian
aislamiento de EPR
De alta resistencia de la capa sobre el núcleo Airbag
El forro de PVC
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B compacto cadena concéntrico de cobre recocido suave elaborado según la norma ASTM
2. conductor de la pantalla: blindaje semiconductor extruido termoestable que es libre de extracción del conductor y se une al aislamiento
3. Aislamiento: aislamiento de EPR a base de naturales de alta resistencia dieléctrica EPROTENAX, combinado con otros materiales y agentes que mejoran la eléctrica y mecánica
características que aseguran la vida cable extendido
4. METÁLICO SHIELD: aplicada helicoidalmente cinta de cobre no magnética (s) sobre blindaje de aislamiento con una superposición mínima de 15%. Una cinta de aluminio / poliéster se aplica longitudinalmente
bajo el escudo de cinta de cobre para la identificación de fase – un conductor con rojo, un conductor con el azul, y un conductor con negro
5. Conductores a tierra: Conductor desnudo de cobre trenzado, uno en cada intersticio, por UL, ICEA y ASTM
6. MONTAJE: Fase identificado conductores blindados cableadas con materiales de carga y conductores de tierra (como se especifica), formando un núcleo de cable firme y cilíndrica. Se aplica una cinta con aglutinante
para mantener la simetría del núcleo y estabilidad mecánica
7. Protección mecánica: de alta resistencia y la capa Airbag alta resistente al aplastamiento cubierta extruida del conjunto de núcleo
PROTECCIÓN 8. química: Una capa de Drylam que consiste en cinta de aluminio y una capa de polímero extrudido resistente a productos químicos se aplica
9. CHAQUETA: La luz solar resistente al cloruro de polivinilo (PVC)
10.STANDARDS: Listado Tipo MV-105 por UL 1072 y MSHA Tipo MP, cumple con los requisitos de 93-639 S-ICEA (WC74). Identificado para uso de la TC. Cable pasa IEEE 1202 / T4 libre (70.000 Btu / hr)
y ICEA T-29-520 (210.000 Btu / h) ensayos a la llama
11.AMPACITY: Basado en una temperatura ambiente de 40 ° C, cable aislado en el aire por la tabla NEC 2008 310.71
12.TEMPERATURE: 105 ° C
13.VOLTAGE: 5 kV
APLICACIONES
Para las instalaciones en ambos lugares expuestos y ocultos, de acuerdo con NEC. Para la instalación en lugares húmedos y secos, de acuerdo con NEC. Puede ser enterrado directamente o
incrustado en el hormigón. Para la instalación de bandejas portacables, bandejas, bastidores metálicos, instalación de la antena y el cable rígido continua apoya de acuerdo con NEC. Adecuado para
elevador vertical. Adecuado para la clase I División 2

Armored Cable AirGuard 5kV

PRYSMIAN CABLES & SYSTEMS
EPR insulation
High-strength Airbag layer over core
PVC jacket
SPECIFICATIONS OF
1. CONDUCTOR: Class B Compact concentric strand soft-drawn annealed copper per ASTM
2. CONDUCTOR SHIELD: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation
3. INSULATION: Natural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical
characteristics assuring extended cable life
4. METALLIC SHIELD: Helically applied non-magnetic copper tape(s) over insulation shield with a minimum overlap of 15%. An aluminum/polyester ribbon is longitudinally applied
under the copper tape shield for phase identification – one conductor with red, one conductor with blue, and one conductor with black
5. GROUNDING CONDUCTORS: Bare stranded copper conductor, one in each interstice, per UL, ICEA and ASTM
6. ASSEMBLY: Phase identified shielded conductors cabled with fillers and grounding conductor (as specified), forming a firm and cylindrical cable core. A binder tape is applied
to maintain core symmetry and mechanical stability
7. MECHANICAL PROTECTION: High-strength and high-crush-resistant Airbag layer extruded cover the core assembly
8. CHEMICAL PROTECTION: A layer of Drylam which consists of aluminum tape and a chemical-resistant extruded polymer layer is applied
9. JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) jacket
10.STANDARDS: Listed Type MV-105 per UL 1072 and MSHA Type MP, meets ICEA S-93-639 (WC74) requirements. Identified for CT use. Cable passes IEEE 1202/FT4 (70,000 Btu/hr)
and ICEA T-29-520 (210,000 Btu/hr) flame tests
11.AMPACITY: Based on an ambient temperature of 40°C, cable isolated in air per 2008 NEC table 310.71
12.TEMPERATURE: 105°C
13.VOLTAGE: 5 kV
APPLICATIONS
For installations in both exposed and concealed locations in accordance with NEC. For installation in wet and dry locations in accordance with NEC. May be directly buried or
embedded in concrete. For installation on cable trays, troughs, metal racks, aerial installation and continuous rigid cable supports in accordance with NEC. Suitable for
vertical riser. Suitable for Class I Division 2 locations

3AE-0203, 3AE-1013, 3AE-2023, 3AE-4043, 3AE-3503, 3AE-5003

Armored Cable AirGuard 5kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

AirGuard 600V

AirGuard 600V

Armored Cable AirGuard 600V

AirGuard 600V

3AR-0803, 3AR-0603, 3AR-0403, 3AR-0203, 3AR-0103, 3AR-1013, 3AR-2023, 3AR-4043, 3AR-2503, 3AR-3503, 3AR-5003

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable AirGuard 600V

Cables y sistemas Prysmian
aislamiento XLP
Airbag capa de alta resistencia
El forro de PVC
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B compacto cadena concéntrico de cobre recocido suave elaborado según la norma ASTM
2. Aislamiento: Polietileno reticulado de alta rigidez dieléctrica (XLP) de aislamiento de ICEA S-95-658 / NEMA WC70 y UL 44 Tipo XHHW-2
3. CONDUCTOR DE TIERRA: Conductor desnudo de cobre trenzado, uno en cada intersticio, por UL, ICEA y ASTM
4. MONTAJE: Conductores de fase identificada cableadas con materiales de carga y el conductor de tierra según la especificación, la formación de un núcleo de cable firme y cilíndrica
5. Protección mecánica: de alta resistencia y la capa Airbag alta resistente al aplastamiento extruida sobre el conjunto del núcleo
6. CHAQUETA: La luz solar resistente al cloruro de polivinilo (PVC)
7. NORMAS: Se enumeran Tipo XHHW-2 individuales. Pasa la IEEE 1202 / T4 libre (70.000 Btu / hr) y (210.000 Btu / h) ensayos a la llama ICEA T-29-520
8. AMPACIDAD: En base a la temperatura ambiente de 30 ° C (86 ° F) y 90 ° C Grado de conductor por la Tabla NEC 310.16 por no más de tres conductores portadores de corriente en la pista de rodadura,
cable, o de la tierra
9. Temperatura: 90 ° C
10.VOLTAGE: 600 V
APLICACIONES
Para la instalación en lugares húmedos y secos, de acuerdo con NEC. Puede ser enterrado o incrustado en el hormigón directamente. Para la instalación de bandejas portacables, bandejas, bastidores de metal, aérea
instalación y cable rígido continua apoya de acuerdo con NEC. Adecuados para aplicaciones de transmisión de frecuencia variable (VFD). Adecuado para aplicaciones verticales verticales.
Adecuado para la clase 1, División 2.

600 V, de tres conductores de cable tipo TC (XHHW-2)

Armored Cable AirGuard 600V

PRYSMIAN CABLES & SYSTEMS
XLP insulation
High-strength Airbag layer
PVC jacket
SPECIFICATIONS OF
1. CONDUCTOR: Class B Compact concentric strand soft-drawn annealed copper per ASTM
2. INSULATION: High dielectric strength Cross-Linked Polyethylene (XLP) insulation to ICEA S-95-658/NEMA WC70 and UL 44 Type XHHW-2
3. GROUNDING CONDUCTORS: Bare stranded copper conductor, one in each interstice, per UL, ICEA and ASTM
4. ASSEMBLY: Phase identified conductors cabled with fillers and grounding conductor per specification, forming a firm and cylindrical cable core
5. MECHANICAL PROTECTION: High-strength and high-crush-resistant Airbag layer extruded over the core assembly
6. JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) jacket
7. STANDARDS: Listed Type XHHW-2 singles. Passes the IEEE 1202/FT4 (70,000 Btu/hr) and ICEA T-29-520 (210,000 Btu/hr) flame tests
8. AMPACITY: Based on ambient temperature of 30°C (86°F) and 90°C conductor rating per NEC Table 310.16 for not more than three current carrying conductors in raceway,
cable, or earth
9. TEMPERATURE: 90°C
10.VOLTAGE: 600 V
APPLICATIONS
For installation in wet and dry locations in accordance with NEC. May be directly buried or embedded in concrete. For installation on cable trays, troughs, metal racks, aerial
installation and continuous rigid cable supports in accordance with NEC. Suitable for variable frequency drive applications (VFD). Suitable for vertical riser applications.
Suitable for Class 1, Division 2 locations.

600 V, three conductor type TC cable (XHHW-2)

3AR-0803, 3AR-0603, 3AR-0403, 3AR-0203, 3AR-0103, 3AR-1013, 3AR-2023, 3AR-4043, 3AR-2503, 3AR-3503, 3AR-5003

Armored Cable AirGuard 600V en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

15kV Three Conductor 133% Insulation Level

15kV Three Conductor 133% Insulation Level

Armored Cable 15kV Three Conductor 133% Insulation Level

15kV Three Conductor 133% Insulation Level

7TPU-0103, 7TPU-1013, 7TPU-2023, 7TPU-3033, 7TPU-4043, 7TPU-2503, 7TPU-3503, 7TPU-5003, 7TPU-7503, 7TPU-10003

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 15kV Three Conductor 133% Insulation Level

El acero galvanizado o aluminio armadura entrelazada
blindado
aislamiento XLP
Las fundas de PVC interior y exterior
PRESUPUESTO
1. CONDUCTOR: Clase B Trenzado, desnudo de cobre, suave
2. conductor de la pantalla: Los cables tienen un blindaje semiconductora sobre el conductor
3. Aislamiento: Polietileno reticulado (XLP) 215 milésimas de pulgada de espesor de aislamiento
4. IDENTIFICACIÓN: Los conductores aislados se identifican por medio de una cinta adhesiva de color (negro, rojo y azul) colocados longitudinalmente bajo el blindaje metálico de cinta de cobre
5. conductor a tierra: Un conductor de tierra trenzado Clase B sin aislamiento está incluido en el conjunto de cables
6. MONTAJE: cables conductores múltiples están montados con cargas adecuadas y cinta con aglutinante
7. chaqueta interior: cloruro de polivinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, una clasificación de -40 ° C
8. Armadura: aluminio o acero galvanizado armadura de enclavamiento
9. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es negro, pero las chaquetas de colores están disponibles bajo petición. Cumple
Ontario Hydro Espec. L-891 SM-77 prueba de la llama y el ensayo de llama vertical de la bandeja FT4
10.AMPACITY: Consultar la IEEE 835-1994 tablas para los valores de ampacidad, y el Código Eléctrico de Canadá factores de corrección
11.STANDARDS: El cable está certificado para CSA C22.2 No. 131 y No. 174 para su uso en CSA Clase 1, División 1 peligrosos (CSA HL clasificación) y CSA C68.3 y pasa el
ensayo de llama vertical de la bandeja FT4
12.TEMPERATURE: -40 ° C a 90 ° C
13.VOLTAGE: 15 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo.

Después de su uso el número de pieza; «SJ» de acero «AJ» para el aluminio, (por ejemplo 7TPU-3033AJ).
Diámetros y pesos pueden variar entre los fabricantes.

Armored Cable 15kV Three Conductor 133% Insulation Level

Galvanized steel or interlocked aluminum armor
Shielded
XLP insulation
Inner and outer PVC jackets
SPECIFICATIONS
1. CONDUCTOR: Class B stranded, bare, soft copper
2. CONDUCTOR SHIELD: Cables have a semiconducting shield over the conductor
3. INSULATION: Cross-Linked Polyethylene (XLP) 215 mils insulation thickness
4. IDENTIFICATION: The insulated conductors are identified by means of a colored tape (black, red and blue) placed longitudinally under the copper tape metallic shield
5. GROUNDING CONDUCTOR: An uninsulated Class B stranded grounding conductor is included in the cable assembly
6. ASSEMBLY: Multiple conductor cables are assembled with suitable fillers and binder tape
7. INNER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C
8. ARMOR: Aluminum or galvanized steel interlocking armor
9. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is black but colored jackets are available on request. Meets
Ontario Hydro Spec. L-891 SM-77 flame test and FT4 vertical tray flame test
10.AMPACITY: Refer to IEEE 835-1994 tables for ampacity values, and the Canadian Electrical Code for correction factors
11.STANDARDS: The cable is certified to CSA C22.2 No. 131 and No. 174 for use in CSA Class 1, Division 1 hazardous locations (CSA HL rated) and CSA C68.3 and passes the
FT4 vertical tray flame test
12.TEMPERATURE: -40°C to 90°C
13.VOLTAGE: 15 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial.

After part number use; «SJ» for steel, «AJ» for aluminum, (e.g. 7TPU-3033AJ).
Diameters and weights may vary among manufacturers.

7TPU-0103, 7TPU-1013, 7TPU-2023, 7TPU-3033, 7TPU-4043, 7TPU-2503, 7TPU-3503, 7TPU-5003, 7TPU-7503, 7TPU-10003

Armored Cable 15kV Three Conductor 133% Insulation Level en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

15kV Three Conductor 100% Insulation Level

15kV Three Conductor 100% Insulation Level

Armored Cable 15kV Three Conductor 100% Insulation Level

15kV Three Conductor 100% Insulation Level

7TP-0203, 7TP-0103, 7TP-1013, 7TP-2023, 7TP-3033, 7TP-4043, 7TP-2503, 7TP-3003, 7TP-3503, 7TP-4003, 7TP-5003, 7TP-6003, 7TP-7503, 7TP-10003

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 15kV Three Conductor 100% Insulation Level

El acero galvanizado o aluminio armadura entrelazada
blindado
aislamiento XLP
Las fundas de PVC interior y exterior
nivel de aislamiento 100%
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, desnudo de cobre, suave
2. conductor de la pantalla: Los cables tienen un blindaje semiconductora sobre el conductor
3. Aislamiento: Polietileno reticulado (XLP), 175 milésimas de pulgada de espesor de aislamiento
4. IDENTIFICACIÓN: Los conductores aislados se identifican por medio de una cinta adhesiva de color (negro, rojo y azul) colocados longitudinalmente inmediatamente debajo de la cinta de cobre escudo
5. blindaje de aislamiento: Consta de una capa semiconductora termoestable además de un componente metálico superponer, en cables multiconductores el componente metálico es un helicoidalmente
aplicada cinta de cobre bañada
6. conductor a tierra: Un conductor de tierra trenzado Clase B sin aislamiento está incluido en el conjunto de cables con cargas adecuadas
7. chaqueta interior: cloruro de polivinilo (PVC)
8. Armadura: aluminio o acero galvanizado armadura de enclavamiento
9. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es rojo, pero las chaquetas de colores están disponibles bajo petición
10.STANDARDS: El cable está certificado para CSA C22.2 No. 131 y No. 174 para su uso en CSA Clase 1, División 1 peligrosos (CSA HL clasificación) y CSA C68.3 y pasa el
ensayo de llama vertical de la bandeja FT4
11.AMPACITY: Consultar la IEEE 835-1994 tablas para los valores de ampacidad, y el Código Eléctrico de Canadá factores de corrección
12.TEMPERATURE: -40 ° C a 90 ° C
13.VOLTAGE: 15 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo.

Armored Cable 15kV Three Conductor 100% Insulation Level

Galvanized steel or interlocked aluminum armor
Shielded
XLP insulation
Inner and outer PVC jackets
100% insulation level
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, soft copper
2. CONDUCTOR SHIELD: Cables have a semiconducting shield over the conductor
3. INSULATION: Cross-Linked Polyethylene (XLP), 175 mils insulation thickness
4. IDENTIFICATION: The insulated conductors are identified by means of a colored tape (black, red and blue) placed longitudinally immediately under the copper tape shield
5. INSULATION SHIELD: Consists of a semiconducting thermosetting layer plus an overlaying metallic component, in multiconductor cables the metallic component is a helically
applied lapped copper tape
6. GROUNDING CONDUCTOR: An uninsulated Class B stranded grounding conductor is included in the cable assembly with suitable fillers
7. INNER JACKET: Polyvinyl Chloride (PVC)
8. ARMOR: Aluminum or galvanized steel interlocking armor
9. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is red but colored jackets are available on request
10.STANDARDS: The cable is certified to CSA C22.2 No. 131 and No. 174 for use in CSA Class 1, Division 1 hazardous locations (CSA HL rated) and CSA C68.3 and passes the
FT4 vertical tray flame test
11.AMPACITY: Refer to IEEE 835-1994 tables for ampacity values, and the Canadian Electrical Code for correction factors
12.TEMPERATURE: -40°C to 90°C
13.VOLTAGE: 15 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial.

After part number use; «SJ» for steel, «AJ» for aluminum, (e.g. 7TP-2023AJ).
Diameters and weights may vary among manufacturers

7TP-0203, 7TP-0103, 7TP-1013, 7TP-2023, 7TP-3033, 7TP-4043, 7TP-2503, 7TP-3003, 7TP-3503, 7TP-4003, 7TP-5003, 7TP-6003, 7TP-7503, 7TP-10003

Armored Cable 15kV Three Conductor 100% Insulation Level en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

5kV Three Conductor Nonshielded

5kV Three Conductor Nonshielded

Armored Cable 5kV Three Conductor Nonshielded

5kV Three Conductor Nonshielded

7TN-0803, 7TN-0603, 7TN-0403, 7TN-0303, 7TN-0203, 7TN-0103, 7TN-1013, 7TN-2023, 7TN-3033, 7TN-4043, 7TN-2503, 7TN-3003, 7TN-3503, 7TN-4003, 7TN-5003, 7TN-6003, 7TN-7503, 7TN-10003

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 5kV Three Conductor Nonshielded

El acero galvanizado o aluminio armadura entrelazada
no apantallado
aislamiento XLP
Las fundas de PVC interior y exterior
nivel de aislamiento 100% o 133%
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, desnudo de cobre, suave
2. conductor de la pantalla: Los cables tienen un blindaje semiconductora sobre el conductor
3. Aislamiento: Polietileno reticulado (XLP), 90 milésimas de pulgada de espesor de aislamiento
4. conductor a tierra: Un conductor de tierra trenzado Clase B sin aislamiento está incluido en el conjunto de cables con cargas adecuadas
5. chaqueta interior: cloruro de polivinilo (PVC)
6. Armadura: aluminio o acero galvanizado armadura de enclavamiento
7. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es de color naranja, pero las chaquetas de colores se puede proporcionar a petición
8. NORMAS: El cable está autorizado a CSA C22.2 No. 131 Teck 90 por cable y Nº 174, para su uso en CSA Clase 1, División 1 peligrosos (CSA HL clasificación) y pasa el
ensayo de llama vertical de la bandeja FT4
9. AMPACIDAD: Basado en 90 ° C la columna de la Tabla 2 del Código Eléctrico Canadiense de 2009, ampacidades permisibles para no más de 3 conductores de cobre en la pista de rodadura o el cable sobre la base de
30 ° C de temperatura ambiente
10.TEMPERATURE: -40 ° C a 90 ° C
11.VOLTAGE: 5 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo.

Después número de uso parte: «SJ» de acero «AJ» para el aluminio, (por ejemplo 7TN-4043AJ).
Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 5kV Three Conductor Nonshielded

Galvanized steel or interlocked aluminum armor
Nonshielded
XLP insulation
Inner and outer PVC jackets
100% or 133% insulation level
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, soft copper
2. CONDUCTOR SHIELD: Cables have a semiconducting shield over the conductor
3. INSULATION: Cross-Linked Polyethylene (XLP), 90 mils insulation thickness
4. GROUNDING CONDUCTOR: An uninsulated Class B stranded grounding conductor is included in the cable assembly with suitable fillers
5. INNER JACKET: Polyvinyl Chloride (PVC)
6. ARMOR: Aluminum or galvanized steel interlocking armor
7. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is orange but colored jackets will be provided upon request
8. STANDARDS: The cable is certified to CSA C22.2 No. 131 Teck 90 cable and No. 174 for use in CSA Class 1, Division 1 hazardous locations (CSA HL rated) and passes the
FT4 vertical tray flame test
9. AMPACITY: Based on 90°C column of Table 2 of the 2009 Canadian Electric Code, allowable ampacities for not more than 3 copper conductors in raceway or cable based on
30°C ambient temperature
10.TEMPERATURE: -40°C to 90°C
11.VOLTAGE: 5 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial.

After part number use: «SJ» for steel, «AJ» for aluminum, (e.g. 7TN-4043AJ).
Diameters and weights may vary among manufacturers

7TN-0803, 7TN-0603, 7TN-0403, 7TN-0303, 7TN-0203, 7TN-0103, 7TN-1013, 7TN-2023, 7TN-3033, 7TN-4043, 7TN-2503, 7TN-3003, 7TN-3503, 7TN-4003, 7TN-5003, 7TN-6003, 7TN-7503, 7TN-10003

Armored Cable 5kV Three Conductor Nonshielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

5kV Single Conductor Nonshielded

5kV Single Conductor Nonshielded

Armored Cable 5kV Single Conductor Nonshielded

5kV Single Conductor Nonshielded

7TM-0601AJ, 7TM-0401AJ, 7TM-0201AJ, 7TM-0101AJ, 7TM-1011AJ, 7TM-2021AJ, 7TM-3031AJ, 7TM-4041AJ, 7TM-2501AJ, 7TM-3001AJ, 7TM-3501AJ, 7TM-4001AJ, 7TM-5001AJ, 7TM-6001AJ, 7TM-7501AJ, 7TM-10001AJ

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 5kV Single Conductor Nonshielded

Aluminio armadura entrelazada
aislamiento XLP
Las fundas de PVC interior y exterior
nivel de aislamiento 100% o 133%
PRESUPUESTO
1. CONDUCTOR: Clase B Trenzado, desnudo de cobre, suave
2. conductor de la pantalla: Los cables tienen un blindaje semiconductora sobre el conductor
3. Aislamiento: Polietileno reticulado (XLP), 90 milésimas de pulgada de espesor de aislamiento
4. Conductor de Tierra: Compuesto de hilos individuales aplicada helicoidalmente sobre el aislamiento
5. chaqueta interior: cloruro de polivinilo (PVC)
6. Armadura: Aluminio-enclavamiento armadura (para cables de un solo conductor para su uso en circuitos de corriente alterna sólo se facilita una armadura de aluminio y no magnéticas [] de aluminio y conectores de bloqueo
frutos secos deben ser usados)
7. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es de color naranja, pero las chaquetas de colores están disponibles bajo petición
8. NORMAS: El cable está autorizado a CSA C22.2 No. 131 y No. 174 para su uso en CSA Clase 1, División 1, lugares peligrosos (CSA HL nominal) y pasa a la bandeja vertical de T4L
prueba de la llama
9. AMPACIDAD: Basado en 90 ° C la columna de la Tabla 1 del Código Eléctrico Canadiense de 2009, ampacidades permisibles para conductores de cobre individuales en el aire libre sobre la base de 30 ° C
temperatura ambiente
10.TEMPERATURE: -40 ° C a 90 ° C
11.VOLTAGE: 5 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo

Nota: El cable blindado disponible.
Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 5kV Single Conductor Nonshielded

Aluminum interlocked armor
XLP insulation
Inner and outer PVC jackets
100% or 133% insulation level
SPECIFICATIONS
1. CONDUCTOR: Class B stranded, bare, soft copper
2. CONDUCTOR SHIELD: Cables have a semiconducting shield over the conductor
3. INSULATION: Cross-Linked Polyethylene (XLP), 90 mils insulation thickness
4. GROUNDING CONDUCTOR: Composed of individual wires applied helically over the insulation
5. INNER JACKET: Polyvinyl Chloride (PVC)
6. ARMOR: Aluminum-interlocking armor (for single conductor cables for use in AC circuits only aluminum armor is provided and non-magnetic [aluminum] connectors and lock
nuts must be used)
7. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is orange but colored jackets are available on request
8. STANDARDS: The cable is certified to CSA C22.2 No. 131 and No. 174 for use in CSA Class 1, Division 1, hazardous locations (CSA HL rated) and passes the FT4 vertical tray
flame test
9. AMPACITY: Based on 90°C column of Table 1 of the 2009 Canadian Electric Code, allowable ampacities for single copper conductors in free air based on 30°C
ambient temperature
10.TEMPERATURE: -40°C to 90°C
11.VOLTAGE: 5 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial

Note: Shielded cable available.
Diameters and weights may vary among manufacturers

7TM-0601AJ, 7TM-0401AJ, 7TM-0201AJ, 7TM-0101AJ, 7TM-1011AJ, 7TM-2021AJ, 7TM-3031AJ, 7TM-4041AJ, 7TM-2501AJ, 7TM-3001AJ, 7TM-3501AJ, 7TM-4001AJ, 7TM-5001AJ, 7TM-6001AJ, 7TM-7501AJ, 7TM-10001AJ

Armored Cable 5kV Single Conductor Nonshielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

1kV Three Conductor

1kV Three Conductor

Armored Cable 1kV Three Conductor

1kV Three Conductor

7TK-1403, 7TK-1203, 7TK-1003, 7TK-0803, 7TK-0603, 7TK-0403, 7TK-0303, 7TK-0203, 7TK-0103, 7TK-1013, 7TK-2023, 7TK-3033, 7TK-4043, 7TK-2503, 7TK-3003, 7TK-3503, 7TK-4003, 7TK-5003, 7TK-6003, 7TK-7503, 7TK-10003

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 1kV Three Conductor

El acero galvanizado o aluminio armadura entrelazada
aislamiento XLP
Las fundas de PVC interior y exterior
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, desnudo de cobre, suave
2. Aislamiento: Polietileno reticulado (XLP)
3. Codificación de color: color de la superficie de codificación es estándar para los tamaños hasta e incluyendo AWG # 6, para mayor número de tamaños estándar de codificación es
4. conductor a tierra: Un conductor de tierra trenzado Clase B sin aislamiento está incluido en el conjunto de cables
5. MONTAJE: cables conductores múltiples están montados con cargas adecuadas y cinta con aglutinante
6. Revestimiento interior: cloruro de polivinilo (PVC)
7. Armadura: aluminio o acero galvanizado armadura de enclavamiento
8. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es negro, pero las chaquetas de colores se puede proporcionar a petición
9. NORMAS: El cable está autorizado a CSA C22.2 No. 131 Teck 90 por cable y Nº 174, para su uso en CSA Clase 1, División 1 peligrosos (CSA HL clasificación) y pasa el
ensayo de llama vertical de la bandeja FT4
10.AMPACITY: Basado en 90 ° C la columna de la Tabla 2 del Código Eléctrico Canadiense de 2009, ampacidades permisibles para no más de 3 conductores de cobre en la pista de rodadura o el cable sobre la base de
30 ° C de temperatura ambiente
11.TEMPERATURE: -40 ° C a 90 ° C
12.VOLTAGE: 1 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo

Después de su uso el número de pieza; «SJ» de acero «AJ» para el aluminio, (por ejemplo 7TK-1013AJ).
Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 1kV Three Conductor

Galvanized steel or interlocked aluminum armor
XLP insulation
Inner and outer PVC jackets
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, soft copper
2. INSULATION: Cross-Linked Polyethylene (XLP)
3. COLOR CODING: Surface color coding is standard for sizes up to and including AWG #6, for larger sizes number coding is standard
4. GROUNDING CONDUCTOR: An uninsulated Class B stranded grounding conductor is included in the cable assembly
5. ASSEMBLY: Multiple conductor cables are assembled with suitable fillers and binder tape
6. INNER JACKET: Polyvinyl Chloride (PVC)
7. ARMOR: Aluminum or galvanized steel interlocking armor
8. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is black but colored jackets will be provided on request
9. STANDARDS: The cable is certified to CSA C22.2 No. 131 Teck 90 cable and No. 174 for use in CSA Class 1, Division 1 hazardous locations (CSA HL rated) and passes the
FT4 vertical tray flame test
10.AMPACITY: Based on 90°C column of Table 2 of the 2009 Canadian Electric Code, allowable ampacities for not more than 3 copper conductors in raceway or cable based on
30°C ambient temperature
11.TEMPERATURE: -40°C to 90°C
12.VOLTAGE: 1 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial

After part number use; «SJ» for steel, «AJ» for aluminum, (e.g. 7TK-1013AJ).
Diameters and weights may vary among manufacturers

7TK-1403, 7TK-1203, 7TK-1003, 7TK-0803, 7TK-0603, 7TK-0403, 7TK-0303, 7TK-0203, 7TK-0103, 7TK-1013, 7TK-2023, 7TK-3033, 7TK-4043, 7TK-2503, 7TK-3003, 7TK-3503, 7TK-4003, 7TK-5003, 7TK-6003, 7TK-7503, 7TK-10003

Armored Cable 1kV Three Conductor en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

1kV Two Conductor

1kV Two Conductor

Armored Cable 1kV Two Conductor

1kV Two Conductor

7TJ-1402, 7TJ-1202, 7TJ-1002, 7TJ-0802, 7TJ-0602, 7TJ-0402, 7TJ-0302, 7TJ-0202, 7TJ-0102, 7TJ-1012, 7TJ-2022, 7TJ-3032, 7TJ-4042, 7TJ-2502, 7TJ-3002, 7TJ-3502, 7TJ-4002, 7TJ-5002, 7TJ-6002, 7TJ-7502

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 1kV Two Conductor

El acero galvanizado o aluminio armadura entrelazada
aislamiento XLP
Las fundas de PVC interior y exterior
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, desnudo de cobre, suave
2. Aislamiento: Polietileno reticulado (XLP)
3. Codificación de color: color de la superficie de codificación es estándar para los tamaños hasta e incluyendo AWG # 6, para el número más grande que los tamaños estándar de codificación es
4. conductor a tierra: Un conductor de tierra trenzado Clase B sin aislamiento está incluido en el conjunto de cables
5. MONTAJE: cables conductores múltiples están montados con cargas adecuadas y cinta con aglutinante
6. Revestimiento interior: cloruro de polivinilo (PVC)
7. Armadura: aluminio o acero galvanizado armadura de enclavamiento
8. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es negro, pero las chaquetas de colores están disponibles bajo petición
9. NORMAS: El cable está autorizado a CSA C22.2 No. 131 para el Tipo de Teck 90 y Nº 174, para su uso en CSA Clase 1, División 1 lugares peligrosos (CSA HL nominal). pasa por cable
IEEE ensayo de llama vertical de bandeja de 1202 / T4L
10.AMPACITY: Basado en 90 ° C la columna de la Tabla 2 del Código Eléctrico Canadiense de 2009, ampacidades permisibles para no más de 3 conductores de cobre en la pista de rodadura o el cable sobre la base de
30 ° C de temperatura ambiente
11.TEMPERATURE: -40 ° C a 90 ° C
12.VOLTAGE: 1 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo.

Después de su uso el número de pieza; «SJ» de acero «AJ» para el aluminio, (por ejemplo 7TJ-1012AJ, 7TJ-3502AJ).
Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 1kV Two Conductor

Galvanized steel or interlocked aluminum armor
XLP insulation
Inner and outer PVC jackets
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, soft copper
2. INSULATION: Cross-Linked Polyethylene (XLP)
3. COLOR CODING: Surface color coding is standard for sizes up to and including AWG #6, for larger than sizes number coding is standard
4. GROUNDING CONDUCTOR: An uninsulated Class B stranded grounding conductor is included in the cable assembly
5. ASSEMBLY: Multiple conductor cables are assembled with suitable fillers and binder tape
6. INNER JACKET: Polyvinyl Chloride (PVC)
7. ARMOR: Aluminum or galvanized steel interlocking armor
8. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is black but colored jackets are available on request
9. STANDARDS: The cable is certified to CSA C22.2 No. 131 for Type Teck 90 and No. 174 for use in CSA Class 1, Division 1 hazardous locations (CSA HL rated). Cable passes
IEEE 1202/FT4 vertical tray flame test
10.AMPACITY: Based on 90°C column of Table 2 of the 2009 Canadian Electric Code, allowable ampacities for not more than 3 copper conductors in raceway or cable based on
30°C ambient temperature
11.TEMPERATURE: -40°C to 90°C
12.VOLTAGE: 1 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial.

After part number use; «SJ» for steel, «AJ» for aluminum, (e.g. 7TJ-1012AJ, 7TJ-3502AJ).
Diameters and weights may vary among manufacturers

7TJ-1402, 7TJ-1202, 7TJ-1002, 7TJ-0802, 7TJ-0602, 7TJ-0402, 7TJ-0302, 7TJ-0202, 7TJ-0102, 7TJ-1012, 7TJ-2022, 7TJ-3032, 7TJ-4042, 7TJ-2502, 7TJ-3002, 7TJ-3502, 7TJ-4002, 7TJ-5002, 7TJ-6002, 7TJ-7502

Armored Cable 1kV Two Conductor en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

1kV Single Conductor

1kV Single Conductor

Armored Cable 1kV Single Conductor

1kV Single Conductor

7TI-0601AJ, 7TI-0401AJ, 7TI-0301AJ, 7TI-0201AJ, 7TI-0101AJ, 7TI-1011AJ, 7TI-2021AJ, 7TI-3031AJ, 7TI-4041AJ, 7TI-2501AJ, 7TI-3001AJ, 7TI-3501AJ, 7TI-4001AJ, 7TI-5001AJ, 7TI-6001AJ, 7TI-7501AJ, 7TI-10001AJ, 7TI-12501AJ, 7TI-15001AJ, 7TI-17501AJ, 7TI-20001AJ

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 1kV Single Conductor

aislamiento XLP
Las fundas de PVC interior y exterior
Aluminio armadura entrelazada
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, hilo pelado de cobre suave, para los cables de un solo conductor es el tamaño mínimo
AWG # 6
2. Aislamiento: Polietileno reticulado (XLP) Tipo RW-90 por CSA C22.2, No. 131
3. Conductor de Tierra: Compuesto de hilos individuales aplicada helicoidalmente sobre el aislamiento
4. Chaqueta interior: cloruro de polivinilo (PVC)
5. Armadura: armadura de aluminio de enclavamiento (para cables de un solo conductor para su uso en circuitos de CA armadura de aluminio sólo es proporcionada y no magnético [de aluminio] y conectores
tuercas de seguridad deben ser utilizados)
6. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es negro, pero las chaquetas de colores se puede proporcionar a petición
7. NORMAS: El cable está autorizado a CSA C22.2 No. 131 Tipo de Teck 90 y Nº 174, para su uso en CSA Clase 1, División 1, lugares peligrosos (CSA HL clasificación) y pasa el
ensayo de llama vertical de la bandeja FT4
8. AMPACIDAD: Basado en 90 ° C la columna de la Tabla 1 del Código Eléctrico Canadiense de 2009, ampacidades permisibles para conductores de cobre individuales en el aire libre sobre la base de 30 ° C
temperatura ambiente
9. Temperatura: -40 ° C a 90 ° C
10.VOLTAGE: 1 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo.

Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 1kV Single Conductor

XLP insulation
Inner and outer PVC jackets
Aluminum interlocked armor
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, soft copper, for single conductor cables the minimum size is
AWG #6
2. INSULATION: Cross-Linked Polyethylene (XLP) Type RW-90 per CSA C22.2, No. 131
3. GROUNDING CONDUCTOR: Composed of individual wires applied helically over the insulation
4. INNER JACKET: Polyvinyl Chloride (PVC)
5. ARMOR: Aluminum interlocking armor (for single conductor cables for use in AC circuits aluminum armor only is provided and non-magnetic [aluminum] connectors and
locknuts must be used)
6. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is black but colored jackets will be provided on request
7. STANDARDS: The cable is certified to CSA C22.2 No. 131 Type Teck 90 and No. 174 for use in CSA Class 1, Division 1, hazardous locations (CSA HL rated) and passes the
FT4 vertical tray flame test
8. AMPACITY: Based on 90°C column of Table 1 of the 2009 Canadian Electric Code, allowable ampacities for single copper conductors in free air based on 30°C
ambient temperature
9. TEMPERATURE: -40°C to 90°C
10.VOLTAGE: 1 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial.

Diameters and weights may vary among manufacturers

7TI-0601AJ, 7TI-0401AJ, 7TI-0301AJ, 7TI-0201AJ, 7TI-0101AJ, 7TI-1011AJ, 7TI-2021AJ, 7TI-3031AJ, 7TI-4041AJ, 7TI-2501AJ, 7TI-3001AJ, 7TI-3501AJ, 7TI-4001AJ, 7TI-5001AJ, 7TI-6001AJ, 7TI-7501AJ, 7TI-10001AJ, 7TI-12501AJ, 7TI-15001AJ, 7TI-17501AJ, 7TI-20001AJ

Armored Cable 1kV Single Conductor en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable
Descarga Aquí este Catálogo
Caddy Erico Mexico, Caddy Nvent Mexico, Erico Mexico, Nvent Mexico,
Subscribase a este sitio