600V Instrumentation

600V Instrumentation

Armored Cable 600V Instrumentation

600V Instrumentation

7I-1601POS, 7I-1601TOS, 7I-1602SPOS, 7I-1604SPOS, 7I-1604STOS, 7I-1608SPOS, 7I-1608STOS, 7I-1612SPOS, 7I-1624SPOS, 7I-1802SPOS, 7I-1804SPOS, 7I-1808SPOS, 7I-1812SPOS, 7I-1824SPOS

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 600V Instrumentation

armadura de aluminio continuo
Aislamiento de PVC / nylon
90 ° C en seco, 600 V
ESPECIFICACIONES DE
1. CONDUCTOR: Bare, cobre recocido según la norma ASTM B-3, clase B hebra según ASTM B-8
2. AISLAMIENTO: Policloruro de Vinilo (PVC / nylon)
3. CÓDIGO DE COLORES: ICEA Método 1, los pares: blanco y negro, y rojo: blanco y negro, tríadas
4. PAR / TRIADA SHIELD: Aluminio cinta / poliéster con conductor de drenaje de cobre estañado
5. Montaje: Los componentes están cableados con rellenos compatibles y una cinta general ligante
6. Pantalla general: Cinta de aluminio / poliéster con conductor de drenaje de cobre estañado
7. chaqueta interior: cloruro de polivinilo (PVC) con el cordón de apertura
8. Armadura:,, aluminio corrugado costura soldada impermeable que es después de la aplicación una prueba de presión
9. CHAQUETA EN GENERAL: cloruro de polivinilo (PVC)
10.STANDARDS: cumple con UL 1569 Requisitos para los cables con revestimiento metálico (tipo MC-HL), cumple con los requisitos de los IEEE 383, IEEE 1202 y UL 1685 70.000 Btu ensayos a la llama
11.TEMPERATURE: 90 ° C
12.VOLTAGE: 600 V
APLICACIONES
Para su uso como cable de instrumentación en áreas donde la resistencia a los productos químicos y la llama es crítica. Puede utilizarse en lugares húmedos o secos instalados en la bandeja abierta, canal o directamente
enterrado. Puede ser instalado de acuerdo con NEC Art. 725.

Nota: POS – PAIR con total Escudo; TOS – Tríada con total Escudo; SPOS – pares con blindaje total blindado.
Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 600V Instrumentation

Continuous aluminum armor
PVC/nylon insulation
90°C dry, 600 V
SPECIFICATIONS OF
1. CONDUCTOR: Bare, annealed copper per ASTM B-3, class B stranded per ASTM B-8
2. INSULATION: Polyvinyl Chloride (PVC/nylon)
3. COLOR CODE: ICEA Method 1, pairs: black and white, triads: black, white and red
4. PAIR/TRIAD SHIELD: Aluminum/polyester tape with tinned copper drain wire
5. ASSEMBLY: Components are cabled with compatible fillers and an overall binder tape
6. OVERALL SHIELD: Aluminum/polyester tape with tinned copper drain wire
7. INNER JACKET: Polyvinyl Chloride (PVC) with rip cord
8. ARMOR: Impervious, seam-welded, corrugated aluminum that is pressure-tested after application
9. OVERALL JACKET: Polyvinyl Chloride (PVC)
10.STANDARDS: Meets UL 1569 requirements for metal-clad cables (Type MC-HL), meets the requirements of the IEEE 383, IEEE 1202 and UL 1685 70,000 Btu flame tests
11.TEMPERATURE: 90°C
12.VOLTAGE: 600 V
APPLICATIONS
For use as instrumentation cable in areas where resistance to chemicals and flame is critical. May be used in wet or dry locations installed in open tray, trough or directly
buried. May be installed in accordance with NEC Art. 725.

Note: POS – Pair with Overall Shield; TOS – Triad with Overall Shield; SPOS – Shielded pairs with overall shield.
Diameters and weights may vary among manufacturers

7I-1601POS, 7I-1601TOS, 7I-1602SPOS, 7I-1604SPOS, 7I-1604STOS, 7I-1608SPOS, 7I-1608STOS, 7I-1612SPOS, 7I-1624SPOS, 7I-1802SPOS, 7I-1804SPOS, 7I-1808SPOS, 7I-1812SPOS, 7I-1824SPOS

Armored Cable 600V Instrumentation en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Archivos
Subscribase a este sitio