Armored Cable 600V Multiconductor Interlocked Armor

Aluminio armadura entrelazada
aislamiento XLP
90 ° C, 600 V
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B trenzado, desnudo, cobre recocido por ASTM B3 y B8
2. Aislamiento: Polietileno reticulado (XLP) Tipo XHHW-2. El código de colores es el método 1,
Tabla E-2 (anteriormente K-2)
3. MONTAJE: Los conductores aislados y un solo cable a tierra de cobre sin aislamiento, desnudo están cableados con rellenos para hacer ronda
4. Armadura: Aluminio enclavada armadura
5. CHAQUETA EN GENERAL: Negro, luz solar resistente al cloruro de polivinilo (PVC)
6. NORMAS: cables cumplen los UL 1685 e IEEE 1202 70.000 Btu / pruebas bandeja de llama vertical hr y están marcados «para uso CT». Los conductores individuales Tipo enumerado XHHW-2 por
UL 44 y el cable está en la lista Tipo de MC por UL 1569 requisitos
7. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra sobre la base de una temperatura ambiente de 30 ° C por 2008 tabla NEC 310.16. Todo multiconductor
valores se han reducido su potencia por 2.008 Tabla NEC 310.15 (B) (2) (a)
8. Temperatura: 90 ° C
9. VOLTAJE: 600 V
APLICACIONES
Para su uso en circuitos de control en plantas industriales, edificios comerciales, y las aplicaciones centrales y subestaciones de servicios públicos. Puede ser instalado en bandejas, bastidores, perchas, etc.,
eliminando la necesidad de conducto. Conveniente para la instalación en interiores y exteriores

A menos que se permita específicamente de la NEC, la protección de sobrecorriente no será superior a 15 A para 14 AWG, 10 A para 12 AWG, 30 A para 10 AWG de cobre.
Nota: Acero galvanizado enclavada armaduras disponibles bajo petición. Uso sufijo «S» en lugar de «A»
Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 600V Multiconductor Interlocked Armor

Aluminum interlocked armor
XLP insulation
90°C, 600 V
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, annealed copper per ASTM B3 and B8
2. INSULATION: Cross-Linked Polyethylene (XLP) Type XHHW-2. Color coding is Method 1,
Table E-2 (formerly K-2)
3. ASSEMBLY: The insulated conductors and a single uninsulated, bare copper ground wire are cabled with fillers to make round
4. ARMOR: Aluminum interlocked armor
5. OVERALL JACKET: Black, sunlight-resistant Polyvinyl Chloride (PVC)
6. STANDARDS: Cables meet the UL 1685 and IEEE 1202 70,000 Btu/hr vertical tray flame tests and are marked «for CT use». Individual conductors listed Type XHHW-2 per
UL 44 and cable is listed Type MC per UL 1569 requirements
7. AMPACITY: Based on not more than three conductors in raceway or cable or earth based on an ambient temperature of 30°C per 2008 NEC table 310.16. All multiconductor
values have been derated per 2008 NEC Table 310.15(B)(2)(a)
8. TEMPERATURE: 90°C
9. VOLTAGE: 600 V
APPLICATIONS
For use in control circuits in industrial plants, commercial buildings, and central and substation utility applications. May be installed in trays, racks, hangers, etc.,
eliminating the need for conduit. Suitable for indoor and outdoor installation

Unless otherwise specifically permitted in the NEC, the overcurrent protection shall not exceed 15 A for 14 AWG, 10 A for 12 AWG, 30 A for 10 AWG copper.
Note: Galvanized steel interlocked armor available upon request. Use suffix «S» instead of «A.»
Diameters and weights may vary among manufacturers

7A-1402A, 7A-1403A, 7A-1404A, 7A-1405A, 7A-1407A, 7A-1409A, 7A-1412A, 7A-1415A, 7A-1419A, 7A-1425A, 7A-1437A, 7A-1202A, 7A-1203A, 7A-1204A, 7A-1205A, 7A-1207A, 7A-1209A, 7A-1212A, 7A-1215A, 7A-1219A, 7A-1224A, 7A-1237A, 7A-1002A, 7A-1003A, 7A-1004A, 7A-1005A

Armored Cable 600V Multiconductor Interlocked Armor en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Archivos
Subscribase a este sitio