XLP PVC
Control Cable XLP PVC
Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx
Control Cable XLP PVC
aislamiento XLP
El forro de PVC
90 ° C, 600 V
PRESUPUESTO
1. CONDUCTORES: Clase B Trenzado de cobre desnudo según la norma ASTM B-3 y B-8
2. Aislamiento: Polietileno (XLPE) por ICEA S-73-532 (NEMA WC57) reticulado, cumple con UL 44 requisitos para VW-1, tipo XHHW-2 conductores
3. CÓDIGO DE COLORES: ICEA Método 1, Tabla E-2 (anteriormente K-2)
4. Montaje: Los conductores están cableados con cargas cuando sea necesario para hacer todo el año, dos cables conductores son planas
5. CHAQUETA EN GENERAL: La luz solar resistente al cloruro de polivinilo (PVC) por UL 1277
6. NORMAS: cumple con UL 1277 por los requisitos para cables TC tipo que tiene XHHW-2 conductores, cables se enumeran para el entierro directo y cumplen con la norma IEEE 1202, IEEE 383 y UL 1685.
70.000 BTU / hr pruebas de llama, así como la ICEA T-29-520, 210.000 BTU / hr ensayos a la llama
7. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra con una temperatura ambiente de 30ºC y una temperatura del conductor de 90 ° C por la Tabla NEC
310.16, los valores han sido reducida en su caso
8. Temperatura: 90 ° C
9. VOLTAJE: 600 V
APLICACIONES
Diseñado por el poder y el control, telemetría, control de relé, el control del tráfico, la distribución, la iluminación y la transmisión de la señal. Puede utilizarse en Clase I, Div. 2 y Clase II, Div. 2
Lugares peligrosos por NEC Art. 501 y 502. Estos cables también cumplen con el art. 392 «Bandejas de cable» y el art. 336 «El poder y la bandeja de cable de control.»
Control Cable XLP PVC
XLP insulation
PVC jacket
90°C, 600 V
SPECIFICATIONS
1. CONDUCTORS: Class B stranded bare copper per ASTM B-3 and B-8
2. INSULATION: Cross-Linked Polyethylene (XLPE) per ICEA S-73-532 (NEMA WC57), meets UL 44 requirements for VW-1, Type XHHW-2 conductors
3. COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2)
4. ASSEMBLY: Conductors are cabled with fillers where necessary to make round, two conductor cables are flat
5. OVERALL JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277
6. STANDARDS: Meets per UL 1277 requirements for Type TC cables having XHHW-2 conductors, cables are listed for direct burial and meet the IEEE 1202, IEEE 383 and UL 1685.
70,000 Btu/hr flame tests as well as the ICEA T-29-520, 210,000 Btu/hr flame tests
7. AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30ºC and a conductor temperature of 90ºC per NEC Table
310.16, the values have been derated where applicable
8. TEMPERATURE: 90ºC
9. VOLTAGE: 600 V
APPLICATIONS
Designed for power and control, telemetering, relay control, traffic control, switching, lighting and signal transmission. May be used in Class I, Div. 2 and Class II, Div. 2
Hazardous Locations per NEC Art. 501 and 502. These cables also conform to Art. 392 «Cable Trays» and Art. 336 «Power and Control Tray Cable.»
2AX-1402, 2AX-1403, 2AX-1404, 2AX-1405, 2AX-1407, 2AX-1409, 2AX-1412, 2AX-1415, 2AX-1419, 2AX-1425, 2AX-1430, 2AX-1437, 2AX-1202, 2AX-1203, 2AX-1204, 2AX-1205, 2AX-1207, 2AX-1209, 2AX-1212, 2AX-1215, 2AX-1219, 2AX-1225, 2AX-1237, 2AX-1002, 2AX-1003, 2AX-1004, 2AX-1005, 2AX-1007, 2AX-1009
XLP PVC en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS
Deja una respuesta