Shielded Substation Control Cable
Control Cable Shielded Substation Control Cable
Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx
Control Cable Shielded Substation Control Cable
aislamiento XLP
chaqueta de CPE
90 ° C, 600 V
PRESUPUESTO
1. CONDUCTORES: Clase B de cobre trenzado según la norma ASTM B-3 y B-8
2. Aislamiento: Polietileno reticulado (XLP) por ICEA S-73-532 (NEMA WC57), cumple con UL 44 requisitos para VW-1, tipo XHHW-2 conductores
3. CÓDIGO DE COLORES: ICEA Método 1, Tabla E-2 (anteriormente K-2) de 14-10 AWG, ICEA Método 4 (números impresos) para 8 AWG
4. Montaje: Los conductores están cableados con cargas cuando sea necesario para hacer que ronda
5. Blindaje:. 0.005 en (5 milésimas de pulgada) aplica longitudinalmente cinta de cobre corrugado
6. CHAQUETA EN GENERAL: La luz del sol polietileno clorado resistente (CPE) por UL 1277
7. Normas: Cumple con los requisitos de UL para los cables TC tipo que tiene XHHW-2 conductores, cables se enumeran para el entierro directo, y cumple la norma IEEE 1202, UL 1685 (70.000 Btu / hr), y
ICEA T-29-520 (210.000 Btu / h) pruebas de llama vertical de la bandeja
8. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura, por cable o de la tierra con una temperatura ambiente de 30ºC por 2008 Cuadro NEC 310.16. Los valores se han reducido su potencia
donde corresponda
9. Temperatura: 90 ° C
10.VOLTAGE: 600 V
APLICACIONES
Diseñado por el poder y el control, telemetría, control de relé, el control del tráfico, la distribución, la iluminación y la transmisión de la señal en aplicaciones de subestaciones. Puede ser utilizado en la clase 1,
Div. 2 de áreas peligrosas por 2008 NEC Art. 501. Estos cables también se ajustan a 2008 NEC artículo 336 de alimentación y la bandeja de cable de control (Tipo TC).
Control Cable Shielded Substation Control Cable
XLP insulation
CPE jacket
90°C, 600 V
SPECIFICATIONS
1. CONDUCTORS: Class B stranded copper per ASTM B-3 and B-8
2. INSULATION: Cross-Linked Polyethylene (XLP) per ICEA S-73-532 (NEMA WC57), meets UL 44 requirements for VW-1, Type XHHW-2 conductors
3. COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2) for 14-10 AWG, ICEA Method 4 (printed numbers) for 8 AWG
4. ASSEMBLY: Conductors are cabled with fillers where necessary to make round
5. SHIELDING: 0.005 in. (5-mil) longitudinally applied corrugated copper tape
6. OVERALL JACKET: Sunlight-resistant Chlorinated Polyethylene (CPE) per UL 1277
7. STANDARDS: Meets UL requirements for Type TC cables having XHHW-2 conductors, cables are listed for direct burial and meets the IEEE 1202, UL 1685 (70,000 Btu/hr), and
ICEA T-29-520 (210,000 Btu/hr) vertical tray flame tests
8. AMPACITY: Based on not more than three conductors in raceway, cable or earth with an ambient temperature of 30ºC per 2008 NEC Table 310.16. The values have been derated
where applicable
9. TEMPERATURE: 90ºC
10.VOLTAGE: 600 V
APPLICATIONS
Designed for power and control, telemetering, relay control, traffic control, switching, lighting and signal transmission in substation applications. May be used in Class 1,
Div. 2 Hazardous Locations per 2008 NEC Art. 501. These cables also conform to 2008 NEC Article 336 Power and Control Tray Cable (Type TC).
2XR-1412LCS-1, 2XR-1407LCS-1, 2XR-1405LCS-1, 2XR-1404LCS-1, 2XR-1403LCS-1, 2XR-1402LCS-1, 2XR-1212LCS-1, 2XR-1207LCS-1, 2XR-1205LCS-1, 2XR-1204LCS-1, 2XR-1203LCS-1, 2XR-1202LCS-1, 2XR-1012LCS-1, 2XR-1007LCS-1, 2XR-1005LCS-1, 2XR-1004LCS-1, 2XR-1003LCS-1, 2XR-1002LCS-1, 2XR-0804LCS-WG-1, 2XR-0803LCS-WG-1
Control Cable Shielded Substation Control Cable en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico
Deja una respuesta