EPR CPE Unishield

EPR CPE Unishield

Power Cable EPR CPE Unishield

EPR CPE Unishield

3USA-0201, 3USA-1011, 3USA-2021, 3USA-4041, 3USA-2501, 3USA-3501, 3USA-5001, 3USA-7501, 3USA-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable EPR CPE Unishield

aislamiento de EPR
chaqueta de CPE
blindado
nivel de aislamiento 133%
Especificaciones de
1. CONDUCTOR: Clase B de trenzado compacto, de cobre desnudo recocido según la norma ASTM B-3 y B-496, escudo cadena es un compuesto semiconductor extruido
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-93-639 (NEMA WC74)
3. SISTEMA DE SHIELD: Combinación de seis hilos de drenaje de cobre y polietileno clorado semiconductora extruida (CPE)
4. NORMAS: Listado Tipo MV-105 por UL 1072. Cumple los requisitos de ICEA S-93-639 / NEMA WC74. Pasa IEEE 1202 (70.000 Btu / hr) / CSA FT4. Tamaños 1/0 y más grandes marcada
La luz del sol pasar Resistentes a UL 1685 de 70.000 BTU ensayo a la llama / hr y se califican «para el uso de CT» UL
5. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
6. Temperatura: 105 ° C
7. Voltaje: 5 kV
APLICACIONES
Para su uso en circuitos de potencia de hasta 5 kV cuando se instala en el aire abierto, conducto, conductos, o enterrado directamente en la tierra, para lugares húmedos y secos. Se utiliza para aplicaciones de potencia en química
plantas, refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas

Power Cable EPR CPE Unishield

EPR insulation
CPE jacket
Shielded
133% insulation level
SPECIFICATIONS of
1. CONDUCTOR: Class B compact stranded, annealed bare copper per ASTM B-3 and B-496, strand shield is an extruded semiconducting compound
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
3. SHIELD SYSTEM: Combination of six copper drain wires and extruded semiconducting Chlorinated Polyethylene (CPE) jacket
4. STANDARDS: Listed Type MV-105 per UL 1072. Meets requirements of ICEA S-93-639 / NEMA WC74. Passes IEEE 1202 (70,000 Btu/hr)/CSA FT4. Sizes 1/0 and larger marked
Sunlight Resistant and pass UL 1685 70,000 Btu/hr flame test and are UL rated «for CT use»
5. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
6. TEMPERATURE: 105°C
7. VOLTAGE: 5 kV
APPLICATIONS
For use in power circuits up to 5 kV when installed in open air, conduit, duct, or buried direct in earth, for wet and dry locations. Used for power applications in chemical
plants, refineries, steel mills, industrial plants, utility substations and generating stations

3USA-0201, 3USA-1011, 3USA-2021, 3USA-4041, 3USA-2501, 3USA-3501, 3USA-5001, 3USA-7501, 3USA-10001

Power Cable EPR CPE Unishield en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Archivos
Subscribase a este sitio