Power Cable VFD

VFD

2ACD-1403, 2ACD-1203, 2ACD-1003, 3ACD-0803, 3ACD-0603, 3ACD-0403, 3ACD-0203, 3ACD-1013, 2ACD-1403-2KV, 2ACD-1203-2KV, 2ACD-1003-2KV, 3ACD-0803-2KV, 3ACD-0603-2KV, 3ACD-0403-2KV, 3ACD-0203-2KV, 3ACD-1013-2KV, 3ACD-2023-2KV, 3ACD-4043-2KV, 3ACD-3503-2KV, 3ACD-5003-2KV

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable VFD

aislamiento XLP
El forro de PVC
escriba TC
90 ° C
UL Listed
PRESUPUESTO
1. CONDUCTOR: Clase B trenzado, de cobre estañado según ASTM B-3, B-33
2. Aislamiento: Polietileno reticulado (XLP) por ICEA S-95-685 (NEMA WC70) cumple con los requisitos de UL
3. CÓDIGO DE COLORES: Los conductores están codificados según el método de ICEA (4 números impresos)
4. Montaje: Tres conductores aislados están cableados con tres motivos sin aislamiento y blindaje total cinta de cobre
5. CHAQUETA EN GENERAL: Negro luz solar resistente al cloruro de polivinilo (PVC) por UL 1277
6. NORMAS: Cumple con los requisitos de UL para cables TC tipo que tiene XHHW-2 conductores. Los cables se enumeran para el entierro directo y cumplen con la norma IEEE 1202, IEEE 383 y UL 1685,
70.000 BTU / hr pruebas de llama, así como la ICEA T-29-520, 210.000 BTU / hr prueba de llama
7. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra por 2008 Cuadro NEC 310.16 con una temperatura del conductor de 90 ° C y una temperatura ambiente
temperatura de 30 ° C. Todos los valores de 4 conductores han sido reducida por 2008 Cuadro NEC 310.15 (B) (2) (a)
8. Temperatura: 90 ° C
9. VOLTAJE: 600 V o 2 kV
APLICACIONES
unidades de frecuencia variable (VFD), también conocido como de velocidad variable o de velocidad ajustable unidades se utilizan para motores de corriente alterna de energía en una variedad de control de movimiento industrial, comercial
aplicaciones de flujo / bombeo, y extrusión. Beneficios del uso de un variador de frecuencia respecto a las unidades tradicionales de CC incluyen control del motor más preciso y una mayor eficiencia de energía. Mientras que hay
muchos beneficios para el uso de variadores de frecuencia, su uso requiere consideraciones especiales para los otros componentes del sistema de accionamiento; sobre todo el cableado de salida del variador. Estos sistemas de accionamiento
requiere cables que están diseñados específicamente para aplicaciones de VFD con el fin de mejorar la fiabilidad del sistema de accionamiento, mientras que la negación de los efectos de RFI / EM

Power Cable VFD

XLP insulation
PVC jacket
Type TC
90°C
UL Listed
SPECIFICATIONS
1. CONDUCTOR: Class B stranded, tinned copper per ASTM B-3, B-33
2. INSULATION: Cross-Linked Polyethylene (XLP) per ICEA S-95-685 (NEMA WC70) meets UL requirements
3. COLOR CODE: Conductors are coded per ICEA Method 4 (printed numbers)
4. ASSEMBLY: Three insulated conductors are cabled with three uninsulated grounds and an overall copper tape shield
5. OVERALL JACKET: Black sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277
6. STANDARDS: Meets the UL requirements for Type TC cables having XHHW-2 conductors. Cables are listed for direct burial and meet the IEEE 1202, IEEE 383, and UL 1685,
70,000 Btu/hr flame tests as well as the ICEA T-29-520, 210,000 Btu/hr flame test
7. AMPACITY: Based on not more than three conductors in raceway or cable or earth per 2008 NEC Table 310.16 with a conductor temperature of 90°C and an ambient
temperature of 30°C. All 4-conductor values have been derated per 2008 NEC Table 310.15(B)(2)(a)
8. TEMPERATURE: 90°C
9. VOLTAGE: 600 V or 2 kV
APPLICATIONS
Variable-frequency drives (VFDs), also known as variable-speed or adjustable-speed drives are used to power AC motors in a variety of industrial motion control, commercial
flow/pumping, and extrusion applications. Benefits of using a VFD over traditional DC drives include more precise motor control and improved power efficiency. While there
are many benefits to using VFDs, their use requires special considerations for other drive system components; especially the drive’s output cabling. These drive systems
require cables that are specifically designed for VFD applications in order to improve drive system reliability while negating the impact of RFI/EM

VFD 600V
2ACD-1403, 2ACD-1203, 2ACD-1003, 3ACD-0803, 3ACD-0603, 3ACD-0403, 3ACD-0203, 3ACD-1013

VFD 2 KV
2ACD-1403-2KV, 2ACD-1203-2KV, 2ACD-1003-2KV, 3ACD-0803-2KV, 3ACD-0603-2KV, 3ACD-0403-2KV, 3ACD-0203-2KV, 3ACD-1013-2KV, 3ACD-2023-2KV, 3ACD-4043-2KV, 3ACD-3503-2KV, 3ACD-5003-2KV

Power Cable VFD en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Archivos
Subscribase a este sitio