5 15 kV Jumper Cable Nonshielded

5 15 kV Jumper Cable Nonshielded

Power Cable 5 15 kV Jumper Cable Nonshielded

5 15 kV Jumper Cable Nonshielded

5R-0201, 5R-0101, 5R-1011, 5R-2021, 5R-4041, 5R-3501, 5R-5001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable 5 15 kV Jumper Cable Nonshielded

aislamiento EPR / chaqueta
ESPECIFICACIONES
1. CONDUCTOR:, cobre cuerda trenzado, flexible y abierto con una cinta semiconductora aplicada sobre
el conductor
2. AISLAMIENTO: Etileno Propileno Red de goma (EPR) por ICEA S-96-659 (NEMA WC71)
3. AMPACIDAD: Basado en un solo conductor aislado aislado en el aire con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C por 2008 Cuadro NEC 310.69
4. Temperatura: 90 ° C
5. TENSIÓN: 5/15 kV
APLICACIONES
cables de puente temporales están destinados a ser utilizados como carburantes flexibles conduce a porciones de derivación de líneas eléctricas aéreas. También se utilizan en equipos donde un no apantallado flexibles
se requiere un cable.

Diámetros y pesos pueden variar entre los fabricantes.
Nota: Cables de puente no deben ser usados en lugar de los cables de media tensión apantallados.
Deben utilizarse sólo en áreas donde el contacto con la gente y conexiones a tierra es limitada.
El acceso a estos cables debe limitarse al personal autorizado.

Power Cable 5 15 kV Jumper Cable Nonshielded

EPR insulation/jacket
SPECIFICATIONS
1. CONDUCTOR: Extra flexible, rope-stranded copper with a semi-conducting tape applied over
the conductor
2. INSULATION: Red Ethylene Propylene Rubber (EPR) per ICEA S-96-659 (NEMA WC71)
3. AMPACITY: Based on insulated single conductor isolated in air with a conductor temperature of 90°C and an ambient temperature of 40°C per 2008 NEC Table 310.69
4. TEMPERATURE: 90°C
5. VOLTAGE: 5/15 kV
APPLICATIONS
Temporary jumper cables are intended for use as flexible power leads to by-pass portions of aerial power lines. They are also used in equipment where a nonshielded flexible
cable is required.

Diameters and weights may vary among manufacturers.
Note: Jumper cables should not be used in place of shielded medium-voltage cables.
They should be used only in areas where contact with people and electrical grounds is limited.
Access to these cables must be limited to authorized personnel.

5R-0201, 5R-0101, 5R-1011, 5R-2021, 5R-4041, 5R-3501, 5R-5001

Power Cable 5 15 kV Jumper Cable Nonshielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Caddy Erico Mexico, Caddy Nvent Mexico, Erico Mexico, Nvent Mexico,
Archivos
Subscribase a este sitio