RHH ST1 KS24194 L2
Power Cable RHH ST1 KS24194 L2
Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx
Power Cable RHH ST1 KS24194 L2
no trenzada
600 V
105 ° C en seco, en húmedo 60 ° C
PRESUPUESTO
1. CONDUCTOR: Clase I modificado agrupado (8 y 6 AWG) o una cuerda-agrupado (4 AWG y mayores) trenzado de cobre estañado se ajuste a los requisitos de la norma ASTM B-33 y UL, tamaños
8 AWG a través de 750 kcmil
2. AISLAMIENTO: 105 ° C puntuación humo limitado, libre de halógenos TelcoHyde 5221 conforme a las normas UL 44, 758 Temas 509 y CSA C22.2 No.210.2 M90, además,
TelcoHyde 5221 cumple con los requisitos de Telcordia Especificación GR-347-CORE, el aislamiento tiene un Índice límite de oxígeno de 35%
3. CARACTERÍSTICAS: Una cinta de aluminio / poliéster opaca se aplicarán sobre el conductor para facilitar la extracción, el humo limitado, no halogenado con aislamiento
4. NORMAS: UL Listed RHH / LS y VW-1 CSA para la prueba de la llama / humo / ST1 FT4, tamaños 1/0 AWG y más grandes son UL «para CT Uso» (bandeja de cables) nominal, libre de plomo y libre de silicona ,
Cumple la directiva europea RoHS, cumple con Telcordia GR-347-CORE
5. Temperatura: 105 ° C en seco, en húmedo 60 ° C
6. VOLTAJE: 600 V, FT4, ST1
APLICACIONES
cable de transmisión de telecomunicaciones. Los cables están diseñados para su uso en circuitos de 600 V CA o CC en las telecomunicaciones oficinas centrales, sitios inalámbricos, estaciones repetidoras, datos
y otros centros de UPS y sistemas de administración de energía. El cable puede ser instalado en bandejas, bastidores, o conducto en aplicaciones horizontales y verticales
Todos los números de referencia requieren descripción del código de color.
Vea la tabla de código de color
Power Cable RHH ST1 KS24194 L2
Non braided
600 V
105°C dry, 60°C wet
SPECIFICATIONS
1. CONDUCTOR: Class I modified bunched (8 and 6 AWG) or rope-bunched (4 AWG and larger) stranded tin-coated copper conforming to ASTM B-33 and UL requirements, sizes
8 AWG thru 750 kcmil
2. INSULATION: 105°C rated limited smoke, zero halogen TelcoHyde 5221 conforming to UL Standards 44, 758 Subjects 509 and CSA C22.2 No.210.2 M90, in addition,
TelcoHyde 5221 complies with the requirements of Telcordia Specification GR-347-CORE, the insulation has a Limiting Oxygen Index of 35%
3. FEATURES: An opaque aluminum/polyester tape shall be applied over the conductor to facilitate stripping, limited smoke, non-halogenated insulated
4. STANDARDS: UL Listed RHH/LS and VW-1 CSA for the FT4/ST1 flame/smoke test, sizes 1/0 AWG and larger are UL «for CT Use» (Cable Tray) rated, lead-free and silicone free,
meets European RoHS directive, complies with Telcordia GR-347-CORE
5. TEMPERATURE: 105°C dry, 60°C wet
6. VOLTAGE: 600 V, FT4, ST1
APPLICATIONS
Telecommunications power cable. The cables are designed for use in 600 V AC or DC circuits in telecommunications central offices, wireless sites, repeater stations, data
centers and other UPS and power management systems. The cable can be installed in trays, racks, or conduit in horizontal and vertical applications
All part numbers require color code description.
See Color Code chart
3BALU-0801-XX, 3BALU-0601-XX, 3BALU-0401-XX, 3BALU-0201-XX, 3BALU-0101-XX, 3BALU-1011-XX, 3BALU-2021-XX, 3BALU-4041-XX, 3BALU-3501-XX, 3BALU-5001-XX, 3BALU-7501-XX
Telecom Cable Color Code Telecom Código de Color del cable
Code Color Codigo Color
02 Black 02 Negro
03 Red 03 Rojo
04 Green 04 Verde
06 Blue 06 Azul
09 Gray (slate) 09 Gris pizarra
03TR Red with black tracer 03TR Rojo con linea negra
06TR Blue with black tracer 06TR Azul con linea negra
09TR Gray with black tracer 09TR Gris con linea negra
Power Cable RHH ST1 KS24194 L2 en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico
Deja una respuesta