Shielded SOOW 90°C

Shielded SOOW 90°C

Portable Cord Shielded SOOW 90°C

Shielded SOOW 90°C

4DS-1802, 4DS-1803, 4DS-1804, 4DS-1805, 4DS-1806, 4DS-1807, 4DS-1808, 4DS-1810, 4DS-1812, 4DS-1602, 4DS-1603, 4DS-1604, 4DS-1605, 4DS-1606, 4DS-1608, 4DS-1610, 4DS-1612, 4DS-1616, 4DS-1630, 4DS-1406, 4DS-1405, 4DS-1404, 4DS-1403, 4DS-1402, 4DS-1206, 4DS-1204, 4DS-1203, 4DS-1202, 4DS-1003

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Portable Cord Shielded SOOW 90°C

aislamiento de goma sintética
chaqueta termoestable
90 ° C, 600 V
ESPECIFICACIONES DE
1. CONDUCTOR: con recubrimiento de estaño, cobre recocido según la norma ASTM B-33
2. AISLAMIENTO: EPR conforme a la norma UL 62
3. CÓDIGO DE COLOR: Por ICEA Método 1, Tabla E-1, excepto 3 / C, que es negro, blanco, verde
4. Montaje: Aislado conductores están cableados con un laico y cargas adecuadas según sea necesario, un separador se aplica en general
5. SHIELD: con recubrimiento de estaño, recocido de cobre trenzado con una cobertura del 85%, un separador se aplica en general
6. CHAQUETA EN GENERAL: Negro, compuesto termoestable resistente al aceite conforme a la norma UL 62
7. NORMAS: UL y CSA
8. AMPACIDAD: Basado en un 30 ° C de temperatura ambiente por 2008 Cuadro NEC 400.5 (A), la columna A, los valores son reducir la potencia (en su caso) de acuerdo con el 2008 NEC 400.5
9. Temperatura: 90 ° C
10.VOLTAGE: 600 V
APLICACIONES
Para su uso como energía portátil y el cable de control. Puede ser utilizado para la prueba o los cables del motor. Además, se ofrece servicio de alta resistencia para herramientas industriales, luces portátiles, cargadores de baterías
y el equipo expuesto a aceites, disolventes y grasas.

Portable Cord Shielded SOOW 90°C

Synthetic rubber insulation
Thermoset jacket
90°C, 600 V
SPECIFICATIONS OF
1. CONDUCTOR: Tin-coated, annealed copper per ASTM B-33
2. INSULATION: EPR conforming to UL Standard 62
3. COLOR CODE: Per ICEA Method 1, Table E-1 except 3/C which is black, white, green
4. ASSEMBLY: Insulated conductors are cabled with a suitable lay and fillers as necessary, a separator is applied overall
5. SHIELD: Tin-coated, annealed copper braid with 85% coverage, a separator is applied overall
6. OVERALL JACKET: Black, oil-resistant thermoset compound conforming to UL Standard 62
7. STANDARDS: UL and CSA Listed
8. AMPACITY: Based on a 30°C ambient temperature per 2008 NEC Table 400.5(A), Column A, the values are derated (where applicable) according to 2008 NEC 400.5
9. TEMPERATURE: 90°C
10.VOLTAGE: 600 V
APPLICATIONS
For use as portable power and control cable. It can be used for test or motor leads. Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers
and equipment exposed to oils, solvents and grease.

4DS-1802, 4DS-1803, 4DS-1804, 4DS-1805, 4DS-1806, 4DS-1807, 4DS-1808, 4DS-1810, 4DS-1812, 4DS-1602, 4DS-1603, 4DS-1604, 4DS-1605, 4DS-1606, 4DS-1608, 4DS-1610, 4DS-1612, 4DS-1616, 4DS-1630, 4DS-1406, 4DS-1405, 4DS-1404, 4DS-1403, 4DS-1402, 4DS-1206, 4DS-1204, 4DS-1203, 4DS-1202, 4DS-1003

Portable Cord Shielded SOOW 90°C en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Archivos
Subscribase a este sitio