Jumper Cable 5 15kV Nonshielded

Jumper Cable 5 15kV Nonshielded

Portable Cable Jumper Cable 5 15kV Nonshielded

Jumper Cable 5 15kV Nonshielded

5R-0201, 5R-0101, 5R-1011, 5R-2021, 5R-4041, 5R-3501, 5R-5001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Portable Cable Jumper Cable 5 15kV Nonshielded

aislamiento EPR / chaqueta
ESPECIFICACIONES
1. CONDUCTOR:, cobre cuerda trenzado, flexible y abierto con una cinta semiconductora aplicada sobre
el conductor
2. AISLAMIENTO: Etileno Propileno Red de goma (EPR) por ICEA S-96-659 (NEMA WC71)
3. AMPACIDAD: Basado en un solo conductor aislado aislado en el aire con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C por 2008 Cuadro NEC 310.69
4. Temperatura: 90 ° C
5. TENSIÓN: 5-15 kV
APLICACIONES
cables de puente temporales están destinados a ser utilizados como carburantes flexibles conduce a porciones de derivación de líneas eléctricas aéreas. También se utilizan en equipos donde un no apantallado flexibles
se requiere un cable

Diámetros y pesos pueden variar entre los fabricantes.
Nota: Cables de puente no deben ser usados en lugar de los cables de media tensión apantallados.
Deben utilizarse sólo en áreas donde el contacto con la gente y conexiones a tierra es limitada.
El acceso a estos cables debe limitarse al personal autorizado

Portable Cable Jumper Cable 5 15kV Nonshielded

EPR insulation/jacket
SPECIFICATIONS
1. CONDUCTOR: Extra flexible, rope-stranded copper with a semi-conducting tape applied over
the conductor
2. INSULATION: Red Ethylene Propylene Rubber (EPR) per ICEA S-96-659 (NEMA WC71)
3. AMPACITY: Based on insulated single conductor isolated in air with a conductor temperature of 90°C and an ambient temperature of 40°C per 2008 NEC Table 310.69
4. TEMPERATURE: 90°C
5. VOLTAGE: 5-15 kV
APPLICATIONS
Temporary jumper cables are intended for use as flexible power leads to by-pass portions of aerial power lines. They are also used in equipment where a nonshielded flexible
cable is required

Diameters and weights may vary among manufacturers.
Note: Jumper cables should not be used in place of shielded medium-voltage cables.
They should be used only in areas where contact with people and electrical grounds is limited.
Access to these cables must be limited to authorized personnel

5R-0201, 5R-0101, 5R-1011, 5R-2021, 5R-4041, 5R-3501, 5R-5001

Portable Cable Jumper Cable 5 15kV Nonshielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable
6 comentarios sobre “Jumper Cable 5 15kV Nonshielded
  1. isaac amorim dice:

    Boa tarde, sou representante de vendos, vendo cabo de cristal para aterramento provisorio, meus clientes utilizam os cabos de jamper temporario para 15kv (jamper by pass 15kv), voces tem distribuição aqui no Brasil ou filial ? fico no aguardo

    • administrador dice:

      Hola Isaac, te informamos que no tenemos filial en Brasil y solo podemos vender el jumper en Mexico, Saludos y que tengas excelente semana.

  2. isaac amorim dice:

    estou precisando de informação do cabo jamper by pass 15kv

  3. isaac amorim dice:

    fico no aguardo

  4. Juan Martin Flores Flores dice:

    hola quisiera saber que precio tiene el de 1/0 y 2/0

  5. Fidel Angel Valiente Fernández dice:

    Por favor indicar la normativa de fabricación y ensayo

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Caddy Erico Mexico, Caddy Nvent Mexico, Erico Mexico, Nvent Mexico,
Archivos
Subscribase a este sitio