SHD GC 2kV

SHD GC 2kV

Mining Cable SHD GC 2kV

SHD GC 2kV

5S-0602, 5S-0402, 5S-0202, 5S-0102, 5S-1002, 5S-2002, 5S-3032, 5S-4002, 5S-2502, 5S-3502, 5S-5002

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Mining Cable SHD GC 2kV

aislamiento de EPR
chaqueta termoestable
90 ° C
ESPECIFICACIONES DE
1. CONDUCTOR:, recocido, cobre estañado cuerda de cadena
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-75-381 (NEMA WC58)
3. SHIELD: Trenzado, escudo de cobre estañado, o una combinación de trenza de blindaje de cobre estañado y nylon
4. CONDUCTOR: trenzado, recubierto, cobre recocido flexible
5. CONTROL DE TIERRA CONDUCTOR: flexible, con aislamiento de cobre adicional hebra recocido con aislamiento de color amarillo
6. MONTAJE: Tres conductores, dos conductores de tierra y un conductor de tierra de verificación, cableados con rellenos que sean necesarias ronda
7. CHAQUETA EN GENERAL: compuesto termoestable
8. NORMAS: Cumple con los requisitos de ICEA S-75-381, aceptada por la MSHA y marcado con el número P del fabricante
9. AMPACIDAD: Basado en una temperatura ambiente de 40 ° C por ICEA S-75-381, la Tabla H-1
10.TEMPERATURE: 90 ° C
11.VOLTAGE: 2 kV
APLICACIONES
Para el uso con los mineros de tajo largo, continuo mineros, cintas transportadoras, bombas, taladros, cortadoras y cargadores. Adecuado para la distribución de alta tensión en las minas donde portátil
Se requiere alimentación

Ver el código de color del conductor al final de esta sección.
Diámetros y pesos pueden variar entre los fabricantes

Mining Cable SHD GC 2kV

EPR insulation
Thermoset jacket
90°C
SPECIFICATIONS OF
1. CONDUCTOR: Rope-stranded, annealed, tinned copper
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-75-381 (NEMA WC58)
3. SHIELD: Braided, tinned copper shield, or combination braid shield of tinned copper and nylon
4. GROUND CONDUCTOR: Flexible stranded, coated, annealed copper
5. GROUND CHECK CONDUCTOR: Insulated extra flexible stranded, annealed copper with yellow insulation
6. ASSEMBLY: Three conductors, two ground conductors and one ground check conductor, cabled with fillers as necessary to make round
7. OVERALL JACKET: Thermoset compound
8. STANDARDS: Meets the requirements of ICEA S-75-381, accepted by MSHA and marked with the manufacturer’s P number
9. AMPACITY: Based on an ambient temperature of 40°C per ICEA S-75-381, Table H-1
10.TEMPERATURE: 90°C
11.VOLTAGE: 2 kV
APPLICATIONS
For use with longwall miners, continuous miners, conveyors, pumps, drills, cutters and loaders. Suitable for high-voltage distribution in mines where portable
power is required

See the Conductor Color Code at the end of this section.
Diameters and weights may vary among manufacturers

5S-0602, 5S-0402, 5S-0202, 5S-0102, 5S-1002, 5S-2002, 5S-3032, 5S-4002, 5S-2502, 5S-3502, 5S-5002

Mining Cable SHD GC 2kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Caddy Erico Mexico, Caddy Nvent Mexico, Erico Mexico, Nvent Mexico,
Archivos
Subscribase a este sitio