15kV Three Conductor 133% Insulation Level
Armored Cable 15kV Three Conductor 133% Insulation Level
Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx
Armored Cable 15kV Three Conductor 133% Insulation Level
Aluminio armadura entrelazada
aislamiento de EPR
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, desnudo, cobre recocido por ASTM B3 y B8, escudo hebra es una
material semiconductor extruido
2. AISLAMIENTO: Caucho de etileno propileno (EPR)
3. Blindaje: Un blindaje de aislamiento semiconductor termoestable extruida se aplica sobre el aislamiento y luego una cinta de cobre sin recubrimiento se aplica helicoidalmente. El método de la fase de
identificación será similar al Método ICEA 3 (1-Negro, 2-Red, 3-Blue)
4. MONTAJE: Los conductores trifásicos están cableados con un Clase B trenzado, cable a tierra sin aislamiento y materiales de relleno para hacer todo el año, se aplica en general una cinta con aglutinante
5. Armadura: Aluminio enclavada armadura
6. CHAQUETA EN GENERAL: Un recubrimiento extruida de polivinilo rojo de vinilo (PVC) se aplica en general que cumpla con los requisitos de resistencia a la luz solar UL
7. NORMAS: Listado Tipo MV-105 por UL 1072 y UL tipo MC por 1569 y se marca para uso de la TC. Cable cumple con los requisitos de ICEA S-93-639 (NEMA WC74) y AEIC CS8.
Cable pasa a UL 1685 y IEEE1202 / T4 libre (70.000 Btu / hr) y ensayos a la llama ICEA T-29-520 (210,000 Btu / hr).
8. AMPACIDAD: Basado en un 5 kV-35 kV de cable de tres conductores aislados en el aire con un índice de temperatura del conductor de 105 ° C y una temperatura ambiente de 40 ° C por
2008 tabla NEC 310.71
9. Temperatura: 105 ° C
10.VOLTAGE: 15 kV
APLICACIONES
Para su uso en circuitos de potencia en plantas industriales, edificios comerciales, y las aplicaciones centrales y subestaciones de servicios públicos. Puede ser instalado en bandejas, bastidores, perchas, etc.,
eliminando la necesidad de conducto. Conveniente para la instalación en interiores y exteriores
Armored Cable 15kV Three Conductor 133% Insulation Level
Aluminum interlocked armor
EPR insulation
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, annealed copper per ASTM B3 and B8, strand shield is an
extruded semiconducting material
2. INSULATION: Ethylene Propylene Rubber (EPR)
3. SHIELDING: An extruded semiconducting thermoset insulation shield is applied over the insulation and then an uncoated copper tape is helically applied. The method of phase
identification will be similar to ICEA Method 3 (1-Black, 2-Red, 3-Blue)
4. ASSEMBLY: The three-phase conductors are cabled with a Class B stranded, uninsulated ground wire and fillers to make round, a binder tape is applied overall
5. ARMOR: Aluminum interlocked armor
6. OVERALL JACKET: An extruded covering of red Polyvinyl Chloride (PVC) is applied overall that meets UL sunlight-resistance requirements
7. STANDARDS: Listed Type MV-105 per UL 1072 and Type MC per UL 1569 and is marked for CT use. Cable meets requirements of ICEA S-93-639 (NEMA WC74) and AEIC CS8.
Cable passes UL 1685 and IEEE1202/FT4 (70,000 Btu/hr) and ICEA T-29-520 (210,000 Btu/hr) flame tests.
8. AMPACITY: Based on a 5 kV-35 kV three-conductor cable isolated in air with a conductor temperature rating of 105°C and an ambient temperature of 40°C per
2008 NEC table 310.71
9. TEMPERATURE: 105°C
10.VOLTAGE: 15 kV
APPLICATIONS
For use in power circuits in industrial plants, commercial buildings, and central and substation utility applications. May be installed in trays, racks, hangers, etc.,
eliminating the need for conduit. Suitable for indoor and outdoor installation