600V Three Conductor Norteck UL CSA

600V Three Conductor Norteck UL CSA

Armored Cable 600V Three Conductor Norteck UL CSA

600V Three Conductor Norteck UL CSA

7XK-0803AJ, 7XK-0603AJ, 7XK-0403AJ, 7XK-0203AJ, 7XK-1013AJ, 7XK-2023AJ, 7XK-4043AJ, 7XK-2503AJ, 7XK-3503AJ, 7XK-5003AJ, 7XK-7503AJ

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 600V Three Conductor Norteck UL CSA

Aluminio armadura entrelazada
aislamiento XLP
Las fundas de PVC interior y exterior
UL 600 V, CSA 1 kV
PRESUPUESTO
1. CONDUCTOR: Clase B trenzado, desnudo, cobre recocido por ASTM B3 y B8
2. Aislamiento: Polietileno reticulado (XLP) por ICEA S-95-658 (NEMA WC70), el tipo RHH / RHW-2 requisitos de UL 44 y RW90 requisitos de CSA. El código de colores es
Método 1, Tabla E-2
3. MONTAJE: Los conductores aislados están cableados con un solo cable a tierra sin aislamiento y materiales de relleno para hacer ronda
4. Chaqueta interior: Negro, luz solar resistente al cloruro de polivinilo (PVC). Chaqueta cumple con los requisitos bajos precios del gas ácido de CSA C22.2 No. 0.3
5. Armadura: Aluminio-entrelazada
6. CHAQUETA EN GENERAL: Negro, luz solar resistente al cloruro de polivinilo (PVC) que se aplica en general por ICEA, chaqueta cumple con los requisitos bajos precios del gas ácido de CSA C22.2 No. 0.3
7. NORMAS: Cables cumplen UL 1685 y IEEE1202 / T4L (70.000 Btu / hr) y ensayos a la llama ICEA T-29-520 (210.000 Btu / h), y están marcados «para uso CT». Los cables también cumplen
CSA -40 ° C impacto fría y ensayo de doblado. Los conductores individuales en UL Tipo RHH / RHW-2 por UL 44 y CSA Tipo enumeran RW90. Los cables que hayan sido mencionados por la UL tipo MC 1569 y
CSA Tipo Teck 90 por CSA C22.2 No. 131
8. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra sobre la base de una temperatura ambiente de 30 ° C por 2008 tabla NEC 310.16
9. Temperatura: 90 ° C
APLICACIONES
Para su uso en circuitos de potencia en plantas industriales, edificios comerciales, y las aplicaciones centrales y subestaciones de servicios públicos. Puede ser instalado en bandejas, bastidores, perchas, etc.,
eliminando la necesidad de conducto. Conveniente para la instalación en interiores y exteriores. Puede ser utilizado en la clase I y II, Div 2 lugares .

Armored Cable 600V Three Conductor Norteck UL CSA

Aluminum interlocked armor
XLP insulation
Inner and outer PVC jackets
UL 600 V, CSA 1 kV
SPECIFICATIONS
1. CONDUCTOR: Class B stranded, bare, annealed copper per ASTM B3 and B8
2. INSULATION: Cross-Linked Polyethylene (XLP) per ICEA S-95-658 (NEMA WC70), Type RHH/RHW-2 requirements of UL 44 and RW90 requirements of CSA. Color coding is
Method 1, Table E-2
3. ASSEMBLY: The insulated conductors are cabled with a single uninsulated ground wire and fillers to make round
4. INNER JACKET: Black, sunlight-resistant Polyvinyl Chloride (PVC). Jacket meets low acid gas requirements of CSA C22.2 No. 0.3
5. ARMOR: Aluminum-interlocked
6. OVERALL JACKET: Black, sunlight-resistant polyvinyl chloride (PVC) applied overall per ICEA, jacket meets low acid gas requirements of CSA C22.2 No. 0.3
7. STANDARDS: Cables meet UL 1685 and IEEE1202/FT4 (70,000 Btu/hr) and ICEA T-29-520 (210,000 Btu/hr) flame tests, and are marked «for CT use». Cables also meet
CSA -40°C cold impact and bend test. Individual conductors UL Listed Type RHH/RHW-2 per UL 44 and listed CSA Type RW90. Completed cables listed Type MC per UL 1569 and
CSA Type Teck 90 per CSA C22.2 No. 131
8. AMPACITY: Based on not more than three conductors in raceway or cable or earth based on an ambient temperature of 30°C per 2008 NEC table 310.16
9. TEMPERATURE: 90°C
APPLICATIONS
For use in power circuits in industrial plants, commercial buildings, and central and substation utility applications. May be installed in trays, racks, hangers, etc.,
eliminating the need for conduit. Suitable for indoor and outdoor installation. May be used in Class I and II, Div 2 locations.

7XK-0803AJ, 7XK-0603AJ, 7XK-0403AJ, 7XK-0203AJ, 7XK-1013AJ, 7XK-2023AJ, 7XK-4043AJ, 7XK-2503AJ, 7XK-3503AJ, 7XK-5003AJ, 7XK-7503AJ

Armored Cable 600V Three Conductor Norteck UL CSA en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

 

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Caddy Erico Mexico, Caddy Nvent Mexico, Erico Mexico, Nvent Mexico,
Archivos
Subscribase a este sitio