2 000V Armored VFD Cables

2 000V Armored VFD Cables

Armored Cable 2 000V Armored VFD Cables

2 000V Armored VFD Cables

7V-1403, 7V-1203, 7V-1003, 7V-0803-3G, 7V-0603-3G, 7V-0403-3G, 7V-0203-3G, 7V-1013-3G, 7V-2023-3G, 7V-4043-3G, 7V-2503-3G, 7V-3503-3G, 7V-5003-3G

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 2 000V Armored VFD Cables

cables de la unidad de CA
armadura de aluminio continuo
aislamiento XLP
PRESUPUESTO
1. CONDUCTOR: Clase B trenzado, desnudo, cobre recocido según la norma ASTM B-3, B-8
2. Aislamiento: Polietileno reticulado (XLP), ICEA 2.000 V niveles de aislamiento, también cumple con CSA RW90 en 6 AWG y más grandes, los conductores se identifican por
Número de codificación «1», «2» y «3» en el aislamiento de la superficie
3. MONTAJE: Los conductores aislados y cable de tierra (s) están cableados con rellenos para hacer ronda
4. Armadura: Un, ondulado vaina de aleación de aluminio de la costura de soldadura continua impermeable de acuerdo con UL 1569, la armadura es una prueba de presión y se encuentra con la tierra
requisitos de NEC artículo 250
5. CHAQUETA EN GENERAL: Negro, luz solar resistente al cloruro de polivinilo (PVC)
6. NORMAS: Cables cumplen con UL e IEEE 383 Pruebas de 70.000 BTU de llama y son marcados «para uso TC», los conductores individuales y los cables terminados se prueban de acuerdo con
requisitos de UL para cables tipo MC-HL
7. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura o el cable o tierra y una temperatura ambiente de 30 ° C por NEC 310.16
8. Temperatura: 90 ° C
9. VOLTAJE: 2.000 V ICEA, 600 V UL
APLICACIONES
energía primaria para todos los tipos de unidades de motor de corriente alterna, en especial entre los inversores PWM y motores de corriente alterna. Cable puede ser utilizado en todos los tipos de instalaciones industriales y de procesamiento.
Este cable se puede utilizar también para muchas otras aplicaciones de energía en la mayoría de entornos.

* 14, 12 y 10 AWG tienen un conductor de puesta a tierra para facilitar la terminación, tres construcciones conductor de tierra también se almacenan, usan el sufijo «-3G».
2.000 V UL para aplicaciones flexibles de cable AC Drive también están disponibles bajo pedido especial.
A menos que se permita específicamente de la NEC, la protección de sobrecorriente no será superior a 15 A para 14 AWG, 20 A para 12 AWG, 30 A para 10 AWG .

Armored Cable 2 000V Armored VFD Cables

AC drive cables
Continuous aluminum armor
XLP insulation
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, bare, annealed copper per ASTM B-3, B-8
2. INSULATION: Cross-Linked Polyethylene (XLP), ICEA 2,000 V insulation levels, also meets CSA RW90 in 6 AWG and larger, conductors are identified by
number coding «1», «2», and «3» on the surface insulation
3. ASSEMBLY: The insulated conductors and ground wire(s) are cabled with fillers to make round
4. ARMOR: An impervious, corrugated continuous seam-welded aluminum alloy sheath in accordance with UL 1569, armor is pressure-tested and meets the grounding
requirements of NEC Article 250
5. OVERALL JACKET: Black, sunlight-resistant Polyvinyl Chloride (PVC)
6. STANDARDS: Cables meet UL and IEEE 383 70,000 Btu Flame Tests and are marked «for CT use», individual conductors and completed cables are tested in accordance with
UL requirements for Type MC-HL cables
7. AMPACITY: Based on not more than three conductors in raceway or cable or earth and an ambient temperature of 30°C per NEC 310.16
8. TEMPERATURE: 90°C
9. VOLTAGE: 2,000 V ICEA, 600 V UL
APPLICATIONS
Primary power for all types of AC motor drives, especially between PWM inverters and AC motors. Cable may be used in all types of industrial and processing facilities.
This cable also can be used for many other power applications in most environments.

*14, 12 and 10 AWG have one grounding conductor to facilitate termination, three grounding conductor constructions are also stocked, use «-3G» suffix.
2,000 V UL for flexible AC Drive cable applications are also available on special order.
Unless otherwise specifically permitted in the NEC, the overcurrent protection shall not exceed 15 A for 14 AWG, 20 A for 12 AWG, 30 A for 10 AWG.

7V-1403, 7V-1203, 7V-1003, 7V-0803-3G, 7V-0603-3G, 7V-0403-3G, 7V-0203-3G, 7V-1013-3G, 7V-2023-3G, 7V-4043-3G, 7V-2503-3G, 7V-3503-3G, 7V-5003-3G

Armored Cable 2 000V Armored VFD Cables en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico